@@ -24,16 +24,31 @@ Before Participant Arrival
2424.. checklist ::
2525
2626 - [ ] Disinfect surfaces (bed, helmet), HPI-coils (gently), and earphones using disinfectant wipes.
27- - [ ] Assemble bedsheet, new earphone covers, and pillow cover .
27+ - [ ] Place clean bedsheet, pillow cover and new earphone covers .
2828 - [ ] Cut 15 pieces of tape (~3-inches in length) for attaching HPI coils.
2929 - [ ] Switch on EyeLink and Eye-tracking computer (if applicable).
3030 - [ ] Test speakers, microphones, response boxes, and screen inside Magnetically Shielded Room (MSR).
31+ - [ ]
3132 - [ ] Call security to request switching off all devices until the session is completed.
3233 - If the participant wears hijab:
3334 - [ ] Request all male researchers to leave the lab for the session duration.
3435 - [ ] Put up the “ladies only” sign on the outside of the lab door.
3536 - [ ] Set up the divider near the door.
3637
38+ MSR Preparation
39+ ^^^^^^^^^^^^^^^
40+
41+ .. checklist ::
42+
43+ - [ ] Ensure that the Marker Box is switched on.
44+ - [ ] Switch on the ProPixx screen from the stimulus computer.
45+ - [ ] Test the speaker and microphone by asking the participant if they are able to hear you.
46+ - [ ] Test the eye-tracker calibration (if applicable).
47+
48+
49+ - [ ] SWITCH OFF THE HEATER
50+
51+
3752Participant Preparation
3853^^^^^^^^^^^^^^^^^^^^^^^
3954
@@ -48,27 +63,18 @@ Participant Preparation
4863 - [ ] Set all devices to Airplane Mode (phones, smart watches).
4964 - [ ] Briefly explain the laser scan process.
5065 - [ ] Equip the participant with a tight-fitting cap to smooth their head shape.
51- - [ ] Mark the participant's head with a felt-tip marker.
66+ - [ ] Place brace around participant's neck covered with paper towel for hygiene
67+ - [ ] Draw the Marker points on the participants head with a felt-tip marker.
5268 - [ ] Ask the participant to close their eyes and remain still during the laser scan.
5369 - [ ] Conduct the laser scan (sweeps and points).
5470 - [ ] Guide the participant to the MSR.
5571 - [ ] Explain the process of attaching HPI coils and the study setup (bed, screen, eye-tracker).
5672 - [ ] Attach the coils to the participant’s head using the guide on the wall and the cable labels.
5773 - [ ] Help the participant lie down carefully on the bed, ensuring the coils do not detach or shift.
58- - [ ] Equip the participant with one earphone .
74+ - [ ] Equip the participant with earphones .
5975 - [ ] Provide the participant with the leg pillow and blanket for comfort.
60-
61- MSR Preparation
62- ^^^^^^^^^^^^^^^
63-
64- .. checklist ::
65-
66- - [ ] Ensure that the Marker Box is switched on.
67- - [ ] Switch on the ProPixx screen from the stimulus computer.
68- - [ ] Test the speaker and microphone by asking the participant if they are able to hear you.
69- - [ ] Test the eye-tracker calibration (if applicable).
7076 - [ ] Switch off the lights and shut the MSR door.
71- - [ ] Switch off the heater.
77+
7278
7379MEG Recording
7480^^^^^^^^^^^^^
@@ -78,9 +84,10 @@ At the MEG Main Computer:
7884.. checklist ::
7985
8086 - [ ] Open MEGLaboratory: click Acquire > Autotuning > OK and wait for the autotuning process to complete.
81- - [ ] Click Acquire > MEG Measurement > Sensor Check and wait 1–2 minutes until signals stabilise .
87+ - [ ] Click Acquire > MEG Measurement > Sensor Check and perform for 30 secs to 1 minute .
8288 - [ ] While waiting, fill in subject details (e.g., “sub-007”).
8389 - [ ] Create the subject folder and copy/paste the folder path so that the data is saved correctly.
90+ - [ ] Disable Sensor Check button
8491 - [ ] Once signals are stable, click Lock.
8592 - [ ] Wait for Lock to complete and for the signals to stabilise again.
8693 - [ ] Take a marker measurement: click MEG Measurement > Marker Measurement > Start.
@@ -98,7 +105,8 @@ After MEG Session
98105 - [ ] Save the .con file to the participant folder.
99106 - [ ] Take a second marker measurement: click Acquire > MEG Measurement > Marker Measurement.
100107 - [ ] Once the MEG measurement is complete, click Unlock.
101- - [ ] Open the MSR door. Assist the participant in sitting up and carefully remove the HPI coils.
108+ - [ ] Switch on the lights and open the MSR door.
109+ - [ ] Assist the participant in sitting up and carefully remove the HPI coils.
102110 - [ ] Guide the participant back to the laser scan room and instruct them to change back into their clothes and collect all belongings.
103111 - [ ] Switch the heater back on.
104112 - [ ] Provide the participant with compensation (if applicable).
@@ -112,6 +120,7 @@ After Participant Leaves
112120 - [ ] Remove and stow used bedsheets and pillow covers in the laundry basket, and used earphone covers in the bin.
113121 - [ ] Disinfect MSR surfaces (bed, helmet), HPI coils (gently), and earphones using disinfectant wipes.
114122 - [ ] Call security to inform them that the session is complete (if finished early).
123+ - [ ] Replace the 15 pieces of tape - ready for the next experiment
115124
116125Saving The Data
117126^^^^^^^^^^^^^^^
0 commit comments