Skip to content

Inconsistent thermal divergence in low-Mach formulation #587

@stgeke

Description

@stgeke

Discussed in #586

Originally posted by bnkeeton September 18, 2024
I've been using the low-Mach formulation in nekRS v23 and found that the evaluation of the thermal divergence seems incorrect for the problem I'm working on. To test this, I've set up a very simple case in a cylindrical domain with a stagnant initial flow superimposed by a spherical hot spot. I run the case for a single small time step, and then output the thermal divergence and compare it to the identical case run with nek5000 by plotting along the line [0,0,0] to [6,0,0]. I have confirmed through separate software that the nek5000 solution is correct. A plot showing the discrepancy is attached, along with both sets of case files. The red curve represents the correct, symmetrical nek5000 thermal divergence, and the blue is nekRS.

One additional item I found interesting is that if you set the thermal conductivity k1 to be constant by changing sigma1=0 in both cases, the two codes then produce identical values for the divergence. I tried inspecting the relevant kernel qtlHex3D but I do not see anything off.

div

nek5000_jet_1.zip
nekrs_jet_1.zip

Thanks,