trontrytel
left a comment
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
LGTM! Left some minor comments about how I would vote to handle the initial condition option.
From the plots I can't tell how accurately we match the paper because the axis etc are slightly different.
Also, do you have a CI case with it already? And if not, would it be useful to add one?
haakon-e
left a comment
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Great work on the PR! Apart from the pressure units, I think everything looks consistent with the paper.
The code suggestions are for improved readability and documentation.
8ade5b6 to
1273629
Compare
|
And I think Wing et. al. (2018) RCEMIP is actually RCEMIPI, not RCEMIPII:) |
a401988 to
ac0dce4
Compare
24d04ae to
622bd24
Compare
6ec9175 to
2123564
Compare
2123564 to
8dbec5b
Compare
In this PR I am adding the initial sounding from the Wing et. al. (2018) RCEMIP paper. This sounding should be used for RCEMIP simulations. There are three options for initial temps of 295K, 300K, and 305K. This PR also adds an option for a cloud resolving model (CRM) setup of RCEMIP with 1M and noneq to ci.
See here the analytic profile derived from an observation from Wing et. al. (2018) (left) and the Julia implementation (right).