Notifications
You must be signed in to change notification settings - Fork 1.5k
Auxiliary fan
OrcaSlicer uses M106 P# / M107 P# to control any fans managed by the slicer.
-
P0: part cooling fan (default layer fan) -
P1(if present): an additional fan -
P2: often used as Aux / CPAP / Booster -
P3(and higher): sometimes Exhaust / Enclosure, etc.
With Klipper you can create macros that translate both the OrcaSlicer numeric fan index P and human‑readable names for your physical fans. This keeps compatibility with generated G‑code (M106 P0 / M106 P2 …) while letting you address fans by name internally.
Warning
Adjust pin names and parameters (power, cycle_time, etc.) to match your hardware.
This is the original basic example where the P index is concatenated (fan0, fan2, fan3). Use it if you don't need custom names:
# Part cooling fan
[fan_generic fan0]
pin: PA7
cycle_time: 0.01
hardware_pwm: false
# Auxiliary fan (comment out if you don't have it)
[fan_generic fan2]
pin: PA8
cycle_time: 0.01
hardware_pwm: false
# Exhaust / enclosure fan (comment out if you don't have it)
[fan_generic fan3]
pin: PA9
cycle_time: 0.01
hardware_pwm: false
[gcode_macro M106]
gcode:
{% set fan = 'fan' + (params.P|int if params.P is defined else 0)|string %}
{% set speed = (params.S|float / 255 if params.S is defined else 1.0) %}
SET_FAN_SPEED FAN={fan} SPEED={speed}
[gcode_macro M107]
gcode:
{% set fan = 'fan' + (params.P|int if params.P is defined else 0)|string %}
{% if params.P is defined %}
SET_FAN_SPEED FAN={fan} SPEED=0
{% else %}
# No P -> turn off typical defined fans
SET_FAN_SPEED FAN=fan0 SPEED=0
SET_FAN_SPEED FAN=fan2 SPEED=0
SET_FAN_SPEED FAN=fan3 SPEED=0
{% endif %}Lets you use descriptive names like CPAP, EXHAUST, etc. Useful if you re‑wire or repurpose fans without changing slicer output. Just keep fan_map updated.
# Example with friendly names + comments showing OrcaSlicer index
[fan_generic CPAP] # fan 0 OrcaSlicer
pin: PB7
max_power: 0.8
shutdown_speed: 0
kick_start_time: 0.100
cycle_time: 0.005
hardware_pwm: False
off_below: 0.10
[fan_generic EXHAUST] # fan 3 OrcaSlicer
pin: PE5
#max_power:
#shutdown_speed:
cycle_time: 0.01
hardware_pwm: False
#kick_start_time:
off_below: 0.2
# If you had another (e.g. P2) add here:
# [fan_generic AUX]
# pin: PXn
[gcode_macro M106]
description: "Set fan speed (Orca compatible)"
gcode:
{% set fan_map = {
0: "CPAP", # Orca P0 → CPAP blower
3: "EXHAUST", # Orca P3 → Exhaust
# 2: "AUX", # Uncomment if you define AUX
} %}
{% set p = params.P|int if 'P' in params else 0 %}
{% set fan = fan_map[p] if p in fan_map else fan_map[0] %}
{% set speed = (params.S|float / 255 if 'S' in params else 1.0) %}
SET_FAN_SPEED FAN={fan} SPEED={speed}
[gcode_macro M107]
description: "Turn off fans. No P = all, P# = specific"
gcode:
{% set fan_map = {
0: "CPAP",
3: "EXHAUST",
# 2: "AUX",
} %}
{% if 'P' in params %}
{% set p = params.P|int %}
{% if p in fan_map %}
SET_FAN_SPEED FAN={fan_map[p]} SPEED=0
{% else %}
RESPOND PREFIX="warn" MSG="Unknown fan index P{{p}}"
{% endif %}
{% else %}
# No P -> turn off all mapped fans
{% for f in fan_map.values() %}
SET_FAN_SPEED FAN={f} SPEED=0
{% endfor %}
{% endif %}- Add / remove entries in
fan_mapto reflect the indexes the slicer may use. - Keep comments like
# fan X OrcaSlicernext to each[fan_generic]for easy correlation. - Tune
max_power,off_below,cycle_timeaccording to fan type (CPAP blower vs axial exhaust).
- From OrcaSlicer:
M106 P0 S255(100% CPAP),M106 P3 S128(~50% EXHAUST). - Turn one off:
M107 P3. Turn all off:M107. - You can still manually use
SET_FAN_SPEED FAN=CPAP SPEED=0.7in the Klipper console.
Pick the variant that best fits your workflow; the advanced version provides extra clarity and flexibility while remaining fully compatible with standard OrcaSlicer G-code output.